230.209

Kuma Vacuum Band Filters

Continuous purification of soiled cooling lubricants, as they are produced when operating machine tools. Purification of liquids from industrial washing plants and dust extraction plants and systems. It makes sense to use such a Vacuum Band filter with high throughput rates, because the throughput in a Vacuum Band Filter is 3 to 4 times higher than in a Gravitation Band Filter while the filtration area is identical. The Vacuum Band Filter consumes less filtration material.

PDF Data Sheet: Kuma Vacuum Band Filters (230.209)

Continuous purification of soiled cooling lubricants, as they are produced when operating machine tools. Purification of liquids from industrial washing plants and dust extraction plants and systems. It makes sense to use such a Vacuum Band filter with high throughput rates, because the throughput in a Vacuum Band Filter is 3 to 4 times higher than in a Gravitation Band Filter while the filtration area is identical. The Vacuum Band Filter consumes less filtration material.

FunctionThe soiled cooling lubricant coming from the machine tool flows into the dirt accumulation part of the filter. A vacuum pump then sucks the cooling lubricant through the filtration material into a clean chamber, retaining dirt particles in the process. The sludge cake forming on the filtration medium creates an increasing vacuum inside the clean chamber. Once a specific pre-adjusted value has been reached, a contact pressure manometer triggers the regeneration process and the sludge cake is evacuated without disrupting the supply of cooling lubricant. Simultaneously, the filtration material is renewed.


Was this information helpful? Provide feedback or ask a quick question about this item.


Your name:
Your company:
E-mail:

For more information regarding this item (Kuma Vacuum Band Filters) or other items, fill out the form below or contact our office directly:

Telephone: 815-962-5600
Fax: 815-962-4600
Location: 304 North Main St, Suite 104, Rockford, IL 61101-1101 USA
Email: infο@ΤΑCRοckfοrd.cοm

Add Comment

Alias

Full name
Position/Title
Company
Telephone
Fax
Email
Mailing Address

Receive a quote or more information on:


Questions or comments:


How did you hear about us?
   Other:


Your preferred method of contact

Related

Automatic Filter Devices
Automatic Filter Devices

The soiled cooling lubricant is conveyed onto the non-woven filter lying in a cavity, via a liquid feed distributor. Owing to the gravitational force the coolant flows through the non-woven filter into a liquid container beneath the band filter. The dirt particles contained in the cooling lubricant are filtered out by the non-woven filter and accumulate in the form of a sludge cake on it. This causes a reduction of the permeability of the filter paper and, therefore, an increase of the liquid level above the filter cavity.

Spring Band Steel
Spring Band Steel

We supply spring band steel either as pre-cut blanks or in coils with thickness values of 0.1 to 3.0 mm and widths of 2.0
- 120 mm. Available materials:
1.4310, 1.4301, C 75 S, C 100 S, CuSn6, CuZn37 as well as CuBe2

Internal Bed Filters
Internal Bed Filters

This type of filter can be used in all treatments where small chips and fine particles are to be filtered out of liquids even if these are of a rather high viscosity. This type of filter has proved its worth and efficiency not only in machining stations, but also in grinding machines, honing machines and wash water conditioning. This filter can be used as an individual system, but also for supplying several machines simultaneously.

Coolant Supply Measuring Instruments
Coolant Supply Measuring Instruments

Quickly and simply check the filtering efficiency of the coolant system. Thanks to replaceable stainless steel filters, the user can adapt the instrument specifically to the filtering of the coolant system. Establishes the present condition of the individual system and displays the actual filter efficiency.

KENOVA Setline V224 Presetting Machines
KENOVA Setline V224 Presetting Machines

The next stage up is the KENOVA Setline V466 with its greater measuring range: 600 mm diameter and 600 mm in length. The Setline V466 shines out among the competition thanks to its modern and ergonomic design as well as to some adjustment related to current market demands. The SK50 precision spindle with vacuum and spindle clamping, mounted on an anti-friction bearing, lays the foundation for precise measurements.

KENOVA Setline V466 Presetting Machines
KENOVA Setline V466 Presetting Machines

The next stage up is the KENOVA Setline V466 with its greater measuring range: 600 mm diameter and 600 mm in length. The Setline V466 shines out among the competition thanks to its modern and ergonomic design as well as to some adjustment related to current market demands. The SK50 precision spindle with vacuum and spindle clamping, mounted on an anti-friction bearing, lays the foundation for precise measurements.

Steep Taper Spindle Gauge Manual
Steep Taper Spindle Gauge Manual

Download PDF for instruction manual.

Control Cabinet Coolers
Control Cabinet Coolers

Electronic control systems are prone to malfunctions if exposed to high temperatures. The cooling is often performed by the blowing-in of external air or via indirect air/air heat exchangers without filters. As these systems always work according to the actual air temperature, the cooling performance is often unsatisfactory, especially during the hot season. The Control Cabinet Cooler has been constructed on the basis of 20 years of experience in refrigeration technology and tens of thousands of industrial cooling plants built for all kinds of applications. The cooling equipment is a unit ready for instant connection, and just an opening needs to be provided in the control cabinet for its installation. The equipment designed according to 19" technology is conceived as ready-to-install units for the standard control cabinets.

Page loaded in 0.0922 seconds.