455.100
HSK Master Setting Gauges
Ensure Repeatable Machine Accuracy, Flawless Tool Presetting, and Perfect Spindle Alignment.
In high-precision machining, minor misalignments lead to catastrophic tool wear, scrapped parts, and unexpected downtime. The TAC Rockford 455 Master Setting / Center Height Gauge is your shop’s frontline defense against alignment errors. The master gauge serves as the ultimate physical baseline for checking both your spindle center height and your spindle orientation.
Beyond basic dimension checks, the 455 series is a critical tool for calibrating M19 spindle orientation commands. By providing precision reference point, it allows you to precisely dial in your machine's M19 position, ensuring seamless, error-free tool changes and perfect synchronization with your automatic tool changer (ATC).
| Taper | L (mm) | D (mm) | f1 (mm) | Part Number | ||||
|---|---|---|---|---|---|---|---|---|
| HSK-A/C/E/T 25 | Contact us | 455.110.125.000 | ||||||
| HSK-A/C/E/T 32 | Contact us | 455.110.132.000 | ||||||
| HSK-A/C/E/T 40 | 60 | 40 | 27 | 455.110.140.000 | ||||
| HSK-A/C/E/T 50 | 70 | 50 | 35 | 455.110.150.000 | ||||
| HSK-A/C/E/T 63 | 80 | 63 | 45 | 455.110.163.000 | ||||
| HSK-A/C/E/T 80 | 80 | 80 | 50 | 455.110.180.000 | ||||
| HSK-A/C/T 100 | 85 | 100 | 60 | 455.110.190.000 | ||||
| HSK-A/C/T 125 | 90 | 125 | 75 | 455.110.192.000 | ||||
| HSK-F63 63 | 80 | 63 | 45 | 455.110.663.000 | ||||
| HSK-F80 80 | 80 | 80 | 50 | 455.110.680.000 |
M19 Spindle Orientation Calibration: The perfect master reference tool to verify and set the M19 command on your CNC machines, protecting your tool changers, drive keys, and spindle tapers from orientation mishaps.
Dual-Purpose Functionality: Seamlessly checks both spindle center alignment and spindle orientation to guarantee consistent part geometry.
Tool Presetter Verification: Doubles as a master reference to calibrate and verify the accuracy of your tool presetters, closing the loop on shop-wide measurements.
Precision: Made from hardened, high-stability tool steel to withstand the shop floor environment while maintaining precision.
For more information regarding this item (HSK Master Setting Gauges) or other items, fill out the form below
or contact our office directly:
Telephone: 815-962-5600
Fax: 815-962-4600
Location: 304 North Main St, Suite 104, Rockford, IL 61101-1101 USA
Email: infο@ΤΑCRοckfοrd.cοm
Related
PSC Master Setting Gauges
Ensure Repeatable Machine Accuracy, Flawless Tool Presetting, and Perfect Spindle Alignment.
In high-precision machining, minor misalignments lead to catastrophic tool wear, scrapped parts, and unexpected downtime. The TAC Rockford 455 Master Setting / Center Height Gauge is your shop’s frontline defense against alignment errors. The master gauge serves as the ultimate physical baseline for checking both your spindle center height and your spindle orientation.
Beyond basic dimension checks, the 455 series is a critical tool for calibrating M19 spindle orientation commands. By providing precision reference point, it allows you to precisely dial in your machine's M19 position, ensuring seamless, error-free tool changes and perfect synchronization with your automatic tool changer (ATC).
KM Master Setting Gauges
Ensure Repeatable Machine Accuracy, Flawless Tool Presetting, and Perfect Spindle Alignment.
In high-precision machining, minor misalignments lead to catastrophic tool wear, scrapped parts, and unexpected downtime. The TAC Rockford 455 Master Setting / Center Height Gauge is your shop’s frontline defense against alignment errors. The master gauge serves as the ultimate physical baseline for checking both your spindle center height and your spindle orientation.
Beyond basic dimension checks, the 455 series is a critical tool for calibrating M19 spindle orientation commands. By providing precision reference point, it allows you to precisely dial in your machine's M19 position, ensuring seamless, error-free tool changes and perfect synchronization with your automatic tool changer (ATC).
HSK Certified Master Taper Gauge
These taper master gauges can be used for zeroing the dial indicators on our HSK Tool Holder Inspection Gauges.
Steep Taper Master Setting Gauges
Ensure Repeatable Machine Accuracy, Flawless Tool Presetting, and Perfect Spindle Alignment.
In high-precision machining, minor misalignments lead to catastrophic tool wear, scrapped parts, and unexpected downtime. The TAC Rockford 455 Master Setting / Center Height Gauge is your shop’s frontline defense against alignment errors. The master gauge serves as the ultimate physical baseline for checking both your spindle center height and your spindle orientation.
Beyond basic dimension checks, the 455 series is a critical tool for calibrating M19 spindle orientation commands. By providing precision reference point, it allows you to precisely dial in your machine's M19 position, ensuring seamless, error-free tool changes and perfect synchronization with your automatic tool changer (ATC).
HSK Dial Indicator Spindle Taper Gauge Manual
Instruction manual for the dial indicator spindle taper gauge (410.310)
HSK Tool Holder Taper 30 Degree Clamping Angle Gauges
Using the calibrated master, the distance of the 30 degree clamping slope relative to l 2 is preset using the dial indicator holder. The tool taper to be measured is placed in the centering piece, allowing the variation of the taper to be measured.
Tool Holder Taper Check Gauges
<b>This product has been replaced by gauge 430.124.</b> <a href="http://tacrockford.com/product/gauges/tool-holder-taper/steep-taper/tool-holder-taper-inspection-gauges/">Click here to link to this product.</a>
<b>Features</b>
-Maximize tool life and spindle life
-Ensure tool holder performance
-Tool holder can be tested with components assembled, and works with retention knob installed
-Includes (A) and (B) indicators with 0.0001" resolution
-Carbide locating pins for long life
-Made with hardened tool steel body
-Comes with master shank (C)
Series 968 HSK Tool Holder Taper Gauges
Series 968 gauges offer comprehensive dimensional verification of HSK tool holders.
Dial Indicator Spindle Taper Gauges
To ensure sustained accuracy at HSK interfaces, we recommend comparison measuring of the geometry of HSK tool shanks and spindles at regular intervals. These checks should become more frequent with an increased change rate at the interface. Calibration on request.




